Hi Friends,
If you use dedicated client in your environment & try to invoke assignment manager through scripting, then you might face errors like:
"No server connect string for Siebel Component SRBroker in Siebel Enterprise SBA_ES, Siebel Server DEV8~ 1-3HU6QN~Campaign Contact"
For this to work correctly, you need to modify your Dedicated client CFG & include following in the InfraObjMgr Section:
[InfraObjMgr]
RequestServerName = dev8
TO
[InfraObjMgr]
RequestServerName = sba_as
Above changes mean that you have to use the 'Logical Siebel Server' Name for RequestServerName instead of Physical Server Name & this Server should have 'Assignment Manager Component' running on it.
After you make these changes in the CFG & restart the client, you will not face this issue again.